Medical Gas Sources

P3 Medical Air Plants

P3 Medical Air Plants

A medical air plant produces the air used by respiratory equipment and critical departments, and is designed to cover the load with the largest compressor out of service. P3 manufactures a UK-made plant family in several configurations to suit facility size.

Overview

What is it?

The plant uses oil-injected screw compressors as standard for low-noise, vibration-free running, with oil-free compressors available on request. It includes a duplex heatless desiccant dryer with an economy circuit, transducer-driven electronic HMI controls, and volt-free normally closed contacts for connection to central alarm systems and BMS. Plants are supplied with all interconnecting pipework and wiring and are factory tested and certified.

Features

  • Available configurations: duplex, triplex, quadruplex, pentaplex and hexaplex
  • Oil-injected screw compressors as standard, oil-free compressors on request
  • Duplex heatless desiccant air dryer with economy circuit
  • Transducer-driven electronic HMI controls configured to minimise running cost
  • Volt-free contacts for connection to central alarm systems and BMS
  • Option for an on-board RTX transmitter for the SDX-15 central alarm
  • Anti-vibration mounts and flexible connections on compressor pipework
  • Meets the requirements of HTM 02-01 and HTM 2022 for medical gas pipeline systems
  • Products from this brand are available according to project requirements and availability.

Applications

  • Hospitals and medical complexes
  • Operating theatres and intensive care units
  • Emergency and inpatient departments
  • Day-surgery centres and clinics
  • Laboratories and supporting medical applications
  • Expansion and medical gas pipeline refurbishment projects
Specifications

Technical specifications

Technical specifications and brands are set per project and per the approved specification — contact us for the technical data suited to your case.

Brand

Brand / Manufacturer

P3 products

Brand
P3
Knowledge

Related technical articles

Medical Air Systems

In preparation

Medical Gas Pipeline Design

In preparation

Medical Gas Maintenance

In preparation

FAQ

Frequently asked questions

How is the number of compressors chosen?

From the facility design load, with the requirement that it is fully covered with the largest compressor out of service — which is why configurations run from duplex to hexaplex.

Have a project or an existing facility that needs an engineering review?

Our engineering team can review your requirement and propose a solution suited to the application, the site and the applicable requirements.